  1. Directional Boring Warning Ribbon | Information by Electrical ...

    Feb 15, 2021 · We are pricing to move an overhead service to underground, I inform AHJ, local inspector for the area that we are considering directional boring due to the circumstances. He asks …

  2. directional drilling | Information by Electrical Professionals for ...

    Feb 24, 2015 · I have a project that needs about 600 feet of PVC conduit to be installed under ground for a feeder out to a detached building. I am assuming directional boring will work for this project …

  3. Directional Boring for electrical conduits. | Information by Electrical ...

    Oct 15, 2015 · I have a project that will use directional boring to install some conduits on the secondary side of a utility transformer. Basically the electrical conduits routed from the utility transformer, under …

  4. Directional Boring cost and method | Information by Electrical ...

    Jun 13, 2015 · I'm being told that I'm going to need to include the cost for directional boring on two sections of a conduit run. I have no Idea how much to charge? The first bore is under a 12' wide side …

  5. Directional boring and warning ribbon | Information by Electrical ...

    May 12, 2003 · Re: Directional boring and warning ribbon While, I believe that the hazard is the same no matter what installation method was used, the code does not requrie a warning ribbon for service …

  6. Directional Boring | Information by Electrical Professionals for ...

    Feb 10, 2011 · When utilizing directional boring, is it possible to pull multiple conduits with one bore? For example multiple 2"C's at one time?

  7. directional boring equipment | Information by Electrical Professionals ...

    Feb 8, 2005 · Gentlemen, where in the codebook does it talk about directional boring equip. and cables being installed? thank you

  8. Directional Boring raceway? | Information by Electrical Professionals ...

    Oct 17, 2008 · I'm doing a directional boring job on monday and I want to make sure I'm not violating 300.5 (K). I am boring under a road 40' long. Is regular SCH-40 rigid PVC conduit listed for …

  9. Underground Boring | Information by Electrical Professionals for ...

    May 15, 2024 · Directional boring can make turns but has turning radius limitations and possibly even number of turns limitations to some extent and I could see soil conditions contributing to what you …

  10. Directional boring and warning ribbon | Information by Electrical ...

    Mar 6, 2004 · Re: Directional boring and warning ribbon These are service conductors. Our customer is a communications utility that owns them back to the transformer, utility ped, or pole.